Treble Adjustment Request:
Adjusts treble serially, from -15dB to +15dB.
"VTR" Function <CR>
Where:
"VTR" VCM Treble Request.
Function "+" "+" = VCM Treble up request
"-" "-" = VCM Treble down request
"?" VCM Treble Status Request Treble Status
The increment and decrement (+,-) requests may contain a single digit that indicates how many dB
steps to increment or decrement. The range of increase or decrease is 2 to 9.
The IT-VCM will respond with a status message that reflects the treble setting after performing the
request (see below).
Example:
VTR +<CR> Adjusts treble up 1dB.
VTR -<CR> Adjusts treble down 1dB.
The response will be:
VTR <value>
Where:
Value = -15dB to +15dB