Bass Adjustment Request:
The Controller will be able to adjust bass serially, from -15dB to +15dB.
"VBS" Function <CR>
Where:
"VBS" VCM Bass Request.
Function "+" "+" = VCM Bass up request
"-" "-" = VCM Bass down request
"?" VCM Bass Status Request Bass Status
The increment and decrement (+,-) requests may contain a single digit that indicates how many dB
steps to increment or decrement. The range of increase or decrease is 2 to 9.
The IT-VCM will respond with a status message that reflects the bass setting after performing the
request (see below).
Example:
VBS +<CR> Adjusts bass up 1dB.
VBS -<CR> Adjusts bass down 1dB.
The response will be:
VBS <value>
Where:
Value = -15dB to +15dB